Establishment of Vascular Restenosis Model Induced by Carotid Artery Balloon Injury in Rats

YANG Bo1, WU Bing1, TANG Jun-ming2, YANG Jian-ye2, CAO Teng1, WANG Jia-ning2   

  1. 1. Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan 430060, China;
    2. Institute of Clinical Medicine Renmin Hospital, Hubei University of Medicine, Shiyan 442000, China
  • Received:2014-12-05 Online:2015-04-25 Published:2015-04-25

摘要: 目的 建立一种简便实用的大鼠颈总动脉球囊拉伤的方法, 为研究物理损伤基础上的血管形态、细胞、生物化学成份等的变化提供稳定可靠的动物模型。方法 30只体质量450~500 g雄性SD大鼠, 异氟烷麻醉后, 分离颈总动脉、颈外动脉和颈内动脉, 并在颈外动脉上做切口,然后用2F球囊导管沿切口插入颈总动脉, 插入约4 cm后, 注入0.02 mL生理盐水使球囊膨胀,轻轻旋转着拉出导管, 反复3次, 致使颈总动脉内膜完全剥脱, 在其损伤后1 d、3 d、7 d、14 d、28 d分别取材, 并进行病理组织学观察。结果 损伤后随着时间的推移新生内膜明显增生, 14 d增生达到高峰。结论 改进的大鼠颈总动脉球囊拉伤模型方法简便, 手术成功率高, 并且血栓形成率低。

关键词: 颈总动脉, 血管再狭窄, 球囊拉伤, 2F球囊导管, 新生内膜增生

Abstract: Objective To establish a simple and useful method of rat carotid artery balloon injury, providing stable and reliable animal model for studying the changes of vessels based on physical damage. Methods Rat common carotid artery, external carotid artery and internal carotid artery were isolated after anesthesia with isoflurane, the artery incision was performed in the external carotid artery, and then the 2F balloon catheter was inserted into common carotid artery in the incision, and pushed about 4 cm. Meanwhile, 0.02 mL normal saline was slightly injected to make the balloon inflate, and then the catheter was gently rotated for all the way when removing. Repeat this operation by three times to completely denude the common carotid artery intima. The changes of histomorphology in carotid artery were observed 1 day, 3 days, 7 days, 14 days, and 28 days after injury. Results Obvious neointima hyperplasia appeared over time after damage, which reached the peak at 14 days. Conclusion The improved rat carotid artery balloon injury model is established with the characteristics of simple operation, high success rate, and low rate of thrombosis.

Key words: Common carotid artery, Vascular restenosis, Balloon withdraw injury, 2F Fogarty arterial embolectomy balloon catheter, Neointimal hyperplasia