›› 2010, Vol. 30 ›› Issue (5): 354-358.

Special Issue: 实验动物资源开发与利用

Previous Articles     Next Articles

Monitoring on Cardiovascular and Physiology Characteristics of Beagle Dog by Telemetry

  

  1. Shanghai Institution of Materia Medica Chinese Academy of Science,Shanghai 201203, China
  • Received:2010-03-17 Online:2010-05-31 Published:2010-05-31

Abstract: Objective To monitor the heart rate、temperature、hemodynamics and electrocardio-gram of beagle dog by telemetry. Methods After two weeks of imbedding the sensor in abdomen muscle, the heart rate、temperature、hemodynamics and electrocardiogram were monitored continuously for 24 hours by Dataquest A.R.T. 2.3, and repeated on next week. Results In all of the monitor process, every index maintain the normal level, but the heart rate rise to the highest about 95.58±15.89 beat per minute at 10 : 00 am, with the systolic pressure、mean arterial blood pressure and diastolic pressure were 152.37± 10.67 mmHg、109.37±5.90 mmHg and 87.73±5.01 mmHg respectively. No differences were found between the two detection(P>0.05). Conclusions The cardiovascular cardiovascular and physiology Characteristics of Beagle dog could been monitored more exactly by telemetry, and the beagle dog was very excited on diet.

Key words: Sensor, Telemetry, Heart rate, Temperature, Hemodynamics